QFAI UNI SHF1
Select variant
Description
Fire resistant
4 – 24 fibres, loose tube
Nonmetallic
SHF1
SHF1
DNV
Product Description
A robust fibre cable suited for harsh ship- and offshore environment. It has no metal content, which leaves it immune to electric and electromagnetic shockwaves. For LAN and WAN installations as well as telecommunication and data transmission on board. UV resistant and rodent protected, SHF1 outer jacket. Fire resistant; operational for 90 min. if exposed to fire.
Fibers
Loose tube
Jelly filled PBTP tube
3,5 mm
Colour code
1- Natural 13- Turquoise 2- Red 14- Red (with black rings) 3- Green 15- Green (with black rings) 4- Yellow 16- Yellow (with black rings) 5- Brown 17- Brown (with black rings) 6- Blue 18- Blue (with black rings) 7- Violet 19- Violet (with black rings) 8- Orange 20- Orange (with black rings) 9- Grey 21- Grey (with black rings) 10- White 22- White (with black rings) 11- Black 23- Pink (with black rings) 12- Pink 24-Turquoise (with black rings)
Fire resistant barrier
Mica tape
Armour
Glass yarn
Jacket
Red or
Orange
SHF1
O.D.
9,5 ± 0,3 [mm]
Weight
95 [kg/km]
Operating temperature normal
-40 – 70 [°C]
Temperature @ installation
-5 – +50 [°C]
Tensile strength
3200
[N]
acc. to IEC 60794-1-2
Crush test
3200 [N/10cm]
acc. to IEC 60794-1-2 (E3)
Impact
10 [J]
acc. to IEC 60794-1-2 (E4)
Min. bending radius
10 [x outer diam]
IEC 60794-1-2 E11A
Min. bending radius flexible
15 [x outer diam]
Halogenfree, max content corrosive and toxic gases
<0.3% when measured according to
IEC 60754-1 & IEC 60754-2
Material properties, insulation and sheath
IEC 60092-360 (359)
Flame resistance
IEC 60332-3-22
Flame retardant
IEC 60332-1-2
Fire resistant
IEC 60331-25
Smoke emission
IEC 61034-1 & IEC 61034-2
Oil and fuel resistant
IEC 60811-404
IRM 902
Test and material
Circuit integrity test IEC 60331-11 / IEC 60331-25 (1000°C, 90 min.) max change of attenuation 2,0 dB
UV-resistant
ASTM-D-2565-16
Certification
DNV
Properties | MM 62.5 OM1 | MM 50 OM2 | MM 50 OM3 | MM 50 OM4 |
---|---|---|---|---|
Core Diameter | 62.5 ± 2.5 μm | 50 ± 2.5 μm | 50 ± 2.5 μm | 50 ± 2.5 μm |
Core non-circularity | < 5% | < 5% | < 5% | < 5% |
Cladding diameter | 125 ± 1.0 μm | 125 ± 1.0 μm | 125 ± 1.0 μm | 125 ± 1.0 μm |
Coating diameter | 242 ± 5 μm | 242 ± 5 μm | 242 ± 5 μm | 242 ± 5 μm |
Cladding non-circularity | <0.7% | <0.7% | <0.7% | <0.7% |
Core/Cladding concentricity error | <1 μm | <1 μm | <1 μm | <1 μm |
Coating/cladding concentricity error | <10 μm | <6 μm | <6 μm | <6 μm |
Numerical Aperture | 0.275 ± 0.015 μm | 0.200 ± 0.015 μm | 0.200 ± 0.015 μm | 0.200 ± 0.015 μm |
Attenuation @ 850 nm | <3.50 db/km | <2.89 dB/km | <2.89 dB/km | <2.89 dB/km |
Attenuation @1300 nm | <1.00 dB/km | <0.80 dB/km | <0.80 dB/km | <0.80 dB/km |
Bandwidth @ 850 nm | >200 MHz*km | >500 MHz*km | >1500 MHz*km | >3500 MHz*km |
Bandwidth @ 1300 nm | >500 MHz*km | >500 MHz*km | >500 MHz*km | >500 MHz*km |
Effective Modal Bandwidth (EMB)@ 850 nm | - | - | >2000 MHz*km | >4700 MHz*km |
Fibre capacity 10GBase-SR | 33 m | 83 m | 300 m | 550 m |
Fibre capacity 10GBase-LX4 | 274 m | 600 m | 1000 m | 1100 m |
Fibre cap. 40GBase-SR4/100Base-RS10 | - | - | 140 m | 170 m |
Proof test | >100kpsi | >100kpsi | >100kpsi | >100kpsi |
Properties | SMR ITU-T G652D | SMR ITU-T G657A | SMR ITU-T G657B / -B2 | SMR NZD ITU-T G655.E |
---|---|---|---|---|
Mode field Diameter @ 1310 nm | 9,0±0,4 μm | 9,0±0,4 μm | 9,0±0,4 μm | - |
Mode field Diameter @ 1550 nm | 10,1±0,5μm | 10,1±0,5μm | 9,9±0,5μm | 9,2±0,5μm |
Cladding diameter | 125±0,7µm | 125±0,7µm | 125±0,7µm | 125±1,0µm |
Coating diameter | 242±7 μm | 242±7 μm | 242±7 μm | 242±7 μm |
Cladding non-circularity | ≤ 0,7 % | ≤ 0,7 % | ≤ 0,7 % | ≤ 0,7 % |
Core/Cladding concentricity error | ≤ 0,5 μm | ≤ 0,5 μm | ≤ 0,5 μm | ≤ 0,5 μm |
Coating/cladding concentricity error | ≤ 12 μm | ≤ 12 μm | ≤ 12 μm | ≤ 12 μm |
Cable Cut off wavelength | ≤ 1260 nm | ≤ 1260 nm | ≤ 1260 nm | ≤ 1300 nm |
Zero dispersion wavelength (λ₀) | 1300-1322 μm | 1300-1322 μm | 1300-1324 μm | 1440 μm |
Dispersion slope (S₀) @ (λ₀) | ≤ 0,090 ps/(nm² * km) | ≤ 0,090 ps/(nm² * km) | ≤ 0,092 ps/(nm² * km) | - |
Chromatic dispersion @ 1285-1330 nm | ≤ 3,5 ps/(nm * km) | ≤ 3,5 ps/(nm * km) | - | - |
Chromatic dispersion @ 1550 nm | ≤ 18 ps /(nm * km) | ≤ 18 ps /(nm * km) | - | - |
Chromatic dispersion @ 1625 nm | ≤ 22 ps/(nm * km) | ≤ 22 ps/(nm * km) | - | - |
Chromatic dispersion @ 1530-1565 nm | - | - | - | 5,5 - 10 ps/(nm * km) |
Chromatic dispersion @ 1565-1625 nm | - | - | - | 5,5 - 10 ps/(nm * km) |
PMD @ 1550 nm | ≤ 0,1 ps/√ km | ≤ 0,1 ps/√ km | ≤ 0,1 ps/√ km | ≤ 0,2 ps/√ km |
Attenuation @ 1310 nm | ≤ 0,35 dB/km | ≤ 0,35 dB/km | ≤ 0,35 dB/km | ≤ 0,40 dB/km |
Attenuation @ 1383nm | ≤ 0,35 dB/km | ≤ 0,35 dB/km | ≤ 0,35 dB/km | ≤ 0,40 dB/km |
Attenuation @ 1550 nm | ≤ 0,25 dB/km | ≤ 0,25 dB/km | ≤ 0,25 dB/km | ≤ 0,25 dB/km |
Attenuation @ 1625 nm | ≤ 0,28 dB/km | ≤ 0,28 dB/km | ≤ 0,28 dB/km | ≤ 0,28 dB/km |
Attenuation with bending: | ||||
Mandreal Radius 15mm @1550 10 turns | - | ≤ 0,25 dB | ≤ 0,03 dB | - |
Mandreal Radius 15mm @1625 10 turns | - | ≤ 1,0 dB | ≤ 1,0 dB | - |
Mandreal Radius 10mm @1550 1 turn | - | ≤ 0,75 dB | ≤ 0,1 dB | - |
Mandreal Radius 10mm @1625 1 turn | - | ≤ 1,5 dB | ≤ 0,2 dB | - |
Mandreal Radius 7,5mm @1550 1 turn | - | - | ≤ 0,5 dB | - |
Mandreal Radius 7,5mm @1625 1 turn | - | - | ≤ 1,0 dB | - |
Proof test | ≥ 100 kpsi | ≥ 100 kpsi | ≥ 100 kpsi | ≥ 100 kpsi |
Number of fibers | Weight [kg/km] | Part.no. |
---|---|---|
G4 50/125 SHF1 - OM4 - orange | 95 | 1028778 |
G6 50/125 SHF1 - OM4 - orange | 95 | 1028779 |
G8 50/125 SHF1 - OM4 - orange | 95 | 1028780 |
G12 50/125 SHF1 - OM4 - orange | 95 | 1028781 |
G24 50/12 SHF1 - OM4 - orange | 105 | 1028782 |
G4 9/125 SHF1 - OS2 - red | 95 | 1028783 |
G6 9/125 SHF1 - OS2 - orange | 95 | 1028784 |
G8 9/125 SHF1 - OS2 - red | 95 | 1028785 |
G8 9/125 SHF1 - OS2 - orange | 95 | 1091127 |
G12 9/125 SHF1 - OS2 - red | 95 | 1028786 |
G24 9/125 SHF1 - OS2 - orange | 105 | 1028787 |
G4 50/125 SHF1 - OM2 - orange | 95 | 1028788 |
G6 50/125 SHF1 - OM2 - orange | 95 | 1028789 |
G8 50/125 SHF1 - OM2 - orange | 95 | 1028790 |
G12 50/125 SHF1 - OM2 - orange | 95 | 1028791 |
G24 50/125 SHF1 - OM2 - orange | 105 | 1028792 |
G4 62,5/125 SHF1 - OM1 - red | 95 | 1028793 |
G4 62,5/125 SHF1 - OM1 - orange | 95 | 1091123 |
G6 62,5/125 SHF1 - OM1 - orange | 95 | 1028794 |
G8 62,5/125 SHF1 - OM1 - orange | 95 | 1028795 |
G12 62,5/125 SHF1 - OM1 - orange | 95 | 1028796 |
G24 62,5/125 SHF1 - OM1 - orange | 105 | 1028797 |
G4 50/125 SHF1 - OM3 - red | 95 | 1091149 |
G6 50/125 SHF1 - OM3 - orange | 95 | 1091148 |
G8 50/125 SHF1 - OM3 - orange | 95 | 1091151 |
G12 50/125 SHF1 - OM3 - red | 95 | 1028776 |
G12 50/125 SHF1 - OM3 - orange | 95 | 1028771 |
G24 50/12 SHF1 - OM3 - red | 105 | 1028777 |
G24 50/12 SHF1 - OM3 - orange | 105 | 1028772 |
Date | Rev. | Description |
---|---|---|
6.12.2016 | 1 | Construction |
10.12.2016 | 2 | Minor dimension change |
28.11.2017 | 3 | Jacket/drawing |
06.02.2018 | 4 | Colour code fibers |
21.03.2018 | 5 | Adding orange SM and dimensions |
14.11.2018 | 6 | dimensions, specs and colour |
05.04.2019 | 7 | Weight in table |
16.03.2021 | 8 | Norms |
Utforsk andre bransjer
NEK Kabel er en ledende leverandør av installasjonskabler for næringsbygg og...
Vi har strøm- og signalkabler som tåler tøffe påkjenninger i krevende...
Når kommunikasjon og strømforsyning skal strekkes mellom anlegg, er robuste,...