RF-LLX-CL 1/2" SHF1
Select variant
Description
Coupling Leaky Cable
50Ω
SHF1
DNV
Product Description
Radiating coaxial cable for tunnels, ships, buildings and other closed areas.
Conductor
Cu-clad Al
4.80 ± 0.05 [mm]
Dielectric
Foamed PE
12.10 ± 0.20 [mm]
Screen
Slotted Cu-tube
13.90 ± 0.25 [mm]
Jacket
SHF1
Outer diam.
16.5 ± 0.5 [mm]
Weight
248 [kg/km]
Operating temperature normal
-20 – +70 [°C]
Temperature @ installation
-20 – +50 [°C]
Characteristic impedance
50±2 [Ω]
Insulation resistance
10000 [MΩ x km]
Tensile strength
1130
[N]
Velocity factor
0,88
Min. bending radius
80 [mm]
Min. bending radius @ installation
125
[mm]
Halogenfree, max content corrosive and toxic gases
IEC 60754-1 & IEC 60754-2
Material properties, insulation and sheath
IEC 60092-360 (359)
, NEK 606
Design and testing standards
IEC 60096-0-1 Ed 3
EN 50288-1
Flame resistance
IEC 60332-3-22 Cat.A , IEC 60332-3-24 Cat.C
Flame retardant
IEC 60332-1-2
Smoke emission
IEC 61034-2
Oil and fuel resistant
IEC 60811-2-1 Mineral Oils, IRM 902: 23ºC / 7 days, 70°C / 4h Diesel, IRM 903: 23ºC / 7 days, 70°C / 4h
UV-resistant
ASTM G 154
CPR classification
Dca-s1,d2,a1
Certification
DNV
Part No.
1092479
Frequency [MHz] | Attenuation [dB/100m ±5%] | Coupling loss 95% [dB±10%] |
---|---|---|
150 | 3.40 | 62/78 |
450 | 6.60 | 70/80 |
900 | 9.50 | 71/82 |
1800 | 13.75 | 77/88 |
2200 | 15.40 | 76/85 |
2400 | 16.00 | 77/87 |
Frequency [MHz] | - |
---|---|
260 – 480 | ≤ 1.25 |
820 – 960 | ≤ 1.25 |
1700 – 1860 | ≤ 1.25 |
1900 – 2050 | ≤ 1.30 |
2100 – 2200 | ≤ 1.30 |
2300 – 2400 | ≤ 1.30 |
Date | Rev. | Description |
---|---|---|
20.04.2020 | 1 | Picture |
15.05.2020 | 2 | VSWR |
29.05.2020 | 3 | Attenuation |
01.06.2022 | 4 | Weight and DNV-GL |
22.12.2023 | 5 | Norms |