RG 59 B/U Marine Flex
Select variant
Description
75Ω Flexible
Al-tape + Cu braid
Steel wire armour
SHF1
DNV
Product Description
Type RG 59 for ship- and offshore applications. Communication and video signals.
Stranded conductor is used for better protection against vibrations and cold bend.
Conductor
Stranded
Plain Cu
7 x 0.20 [mm]
Dielectricum
Low density PE
3.7 ± 0.10 [mm]
Screen
Al-polyester + Al tape
100 [% optical coverage]
Screen
Cu-braid
91 [% optical coverage]
Jacket
Black
SHF1
O.D.
6.20 ± 0.20 [mm]
Weight
52 [kg/km]
Jacket marking
NEK Kabel – RG 59 B/U Marine Flex – DD/MM/YY – batch **** – ****m
Operating temperature normal
-40 – +80 [°C]
Characteristic impedance
75 ± 3 [Ω]
Braid Resistance
10 [Ω/km]
Conductor resistance
82 [Ω/km]
Test voltage
5 [kV]
Capacitance
67 [pF/m]
Velocity factor
0,66
Min. bending radius
5 [x outer diam]
Min. bending radius flexible
10 [x outer diam]
Halogenfree, max content corrosive and toxic gases
IEC 60754-1 & IEC 60754-2
Material properties, insulation and sheath
IEC 60092-359
Flame resistance
IEC 60332-3-22 Cat.A
Flame retardant
IEC 60332-1-2
Toxic gases max.
IEC 60092-359
Smoke emission
IEC 61034-2
Oil and fuel resistant
IEC 60811-3-1
UV-resistant
UL 1581, ISO 4892
Certification
DNV
Part No.
1092218
Frequency MHz | Attenuation dB/100m |
---|---|
5 | 2.6 |
10 | 3.3 |
50 | 7.3 |
100 | 10.8 |
200 | 15.3 |
400 | 21.9 |
500 | 25.1 |
600 | 27.4 |
800 | 32.0 |
1000 | 36.3 |
1350 | 42.6 |
1500 | 46.0 |
1750 | 50.5 |
2150 | 57.5 |
2250 | 58.7 |
2500 | 62.4 |
2750 | 65.8 |
3000 | 70.7 |
MHz | dB |
---|---|
30 – 300 | > 30 |
300 – 600 | > 25 |
600 – 1000 | > 22 |
1000 – 2000 | > 20 |
2000 – 3000 | > 16 |
MHz | dB |
---|---|
100 – 900 | > 90 |
900 – 2000 | > 80 |
2000 – 3000 | > 70 |
Date | Rev. | Description |
---|---|---|
03.05.2023 | 1 | Norms & attenuation |
Related Products
Utforsk andre bransjer
NEK Kabel er en ledende leverandør av installasjonskabler for næringsbygg og...
Vi har strøm- og signalkabler som tåler tøffe påkjenninger i krevende...
Når kommunikasjon og strømforsyning skal strekkes mellom anlegg, er robuste,...